J - H(st)H...Bd (FLEXIBLE)

Application: 
It is used as signal and data communication cable in communication systems in indoor installations. These types of cables do not emit flammable, poisonous or corrosive gases during the fire.
Cable Construction: 
  • Conductor
    : Electrolytic Flexible Copper
  • Insulation
    : HFFR Compound
  • Twisting
    : Twisting of quadruple groups as layers
  • Separating Tape
    : Polyester Tape
  • Screen
    : Tinned Cooper Grounding Wire + Al-Pes Tape
  • Outer Sheath
    : HFFR Compound
  • Packing
    : 100/500/1000 m
Electrical Data: 
  • Conductor Resistance
    : 0.50 mm² : 39 Ω / Km , 0.75 mm² : 26 Ω / Km , 1.00 mm² : 19,5 Ω / Km , 1.50 mm² : 13.3 Ω / Km
  • Insulation Resistance
    :  >100 M Ω/km
  • Effective Capacity
    : 120 nF / km
  • Capacity Disequilibrium
    : 300 pF / 100mt
  • Operating Voltage
    : 300 V
  • Testing Voltage
    : 1000 V
  • Bending Radius
    : 10 x D
  • Operating Temperature
    : -30ºC ~ + 70ºC
  • Smoke Density Test
    : IEC 61034-2 / VDE 0482-1034-2 / EN 61034-2
  • Corrosive Gas Test
    : IEC 60754-2 / VDE 0482-267-2-3 / EN 50267-2-3
  • Hallogen-free Test
    : IEC 60754-1 / VDE 0482-267-2-1 / EN 50267-2-1
  • Flame Retardancy Test
    : IEC 60332-1-2 / VDE 0482-332-1-2 / EN 60332-1-2
Core Quantity x Nominal Cross-Section (mm²)Outer Diameter (mm)Cable Weight (kg/km)Standard Length (mt)
1x2x0,505.4033100/500/1000
2x2x0,506.1050100/500/1000
4x2x0,508.0092100/500/1000
1x2x0,755.8040100/500/1000
2x2x0,756.8066100/500/1000
4x2x0,758.90121100/500/1000
1x2x1,006.4050100/500/1000
2x2x1,007.3078100/500/1000
4x2x1,009.60146100/500/1000
1x2x1,507.4067100/500/1000
2x2x1,508.50109100/500/1000
4x2x1,5011.30206100/500/1000